Manifold Gauge Set

Digital Gauge Refrigeration Manifold for HVAC Vacuum Temp Pressure R134a A/C Set

Digital Gauge Refrigeration Manifold for HVAC Vacuum Temp Pressure R134a A/C Set
Digital Gauge Refrigeration Manifold for HVAC Vacuum Temp Pressure R134a A/C Set
Digital Gauge Refrigeration Manifold for HVAC Vacuum Temp Pressure R134a A/C Set
Digital Gauge Refrigeration Manifold for HVAC Vacuum Temp Pressure R134a A/C Set
Digital Gauge Refrigeration Manifold for HVAC Vacuum Temp Pressure R134a A/C Set
Digital Gauge Refrigeration Manifold for HVAC Vacuum Temp Pressure R134a A/C Set
Digital Gauge Refrigeration Manifold for HVAC Vacuum Temp Pressure R134a A/C Set
Digital Gauge Refrigeration Manifold for HVAC Vacuum Temp Pressure R134a A/C Set
Digital Gauge Refrigeration Manifold for HVAC Vacuum Temp Pressure R134a A/C Set
Digital Gauge Refrigeration Manifold for HVAC Vacuum Temp Pressure R134a A/C Set
Digital Gauge Refrigeration Manifold for HVAC Vacuum Temp Pressure R134a A/C Set
Digital Gauge Refrigeration Manifold for HVAC Vacuum Temp Pressure R134a A/C Set

Digital Gauge Refrigeration Manifold for HVAC Vacuum Temp Pressure R134a A/C Set   Digital Gauge Refrigeration Manifold for HVAC Vacuum Temp Pressure R134a A/C Set

Digital Refrigeration Manifold for HVAC Vacuum Temperature Pressure Tester Set. AUTOOL LM120+ is an auxiliary instrument for the installation, testing and maintenance of refrigeration equipment such as air conditioners and cold storage.

The instrument has double pressure test, dual temperature test, digital readout, multi-unit switching, multi-mode function and built-in refrigerant database. AUTOOL LM120+ HVAC Pressure Temperature Vacuum Tester Features. [Evaporation Pressure&Tempe test]: The maximum pressure when the refrigerant changes from liquid to gas. The lowest temp when the liquid becomes gaseous.

The lower the pressure and temp of the evaporation are, the more efficient the refrigeration cycle and the greater the refrigeration capacity will do. [Condensing Pressure&Temp Test]: The minimum pressure when the refrigerant changes from gas to liquid, and the maximum temp when the gas changes to liquid. The lower the pressure and temp of condensation are, the higher the efficiency of the refrigeration cycle and the greater the refrigerant capacity will do. [High/Low-pressure temperature test]: The temperature of the AUTOOL LM120/LM120+ Digital Refrigeration Manifold in the high/low-pressure pipelines of the air conditioning system. [Pressure leakage test]: Calculate the pressure difference between the initial test pressure and the second test pressure to determine if the refrigerant is leaking.

[Type Setting&Observable window]: AUTOOL LM120/LM120+ Digital Refrigeration Manifold can be set according to the type of refrigerant that the car needs to fill; The refrigerant filing status can be observed through a visible window. [Smart Digital Display]: The intelligent digital display of the test results of the pressure and temperature of the air conditioning system reduces the cost of time.

Pressure test unit: Kpa; Mpa; bar; inHg; PSI. Pressure test range: 0 Kpa - 6000 Kpa. Pressure test resolution: 1 Kpa. Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt. Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;).

Vacuum test unit: Kpa; Mpa; bar; inHg; PSI. Vacuum test range: -101 Kpa - 0 Kpa. Vacuum test resolution: 1 Kpa. Temperature test unit: °C (Celsius), °F (Fahrenheit).

Temperature test range: -40°C-150°C (-40°F-302°F). 0.1°C (-40°C-99.9°C), 1°C (100°C-150°C). 0.1°F (-40°F-99.9°F), 1°F (100°F-302°F). Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt. Built-in 89 kinds of refrigerant NIST: According to American NIST standard. Power Supply: 4 X 1.5V SIZE. AA / LR6 Battery not include. EC/EN61010-1 safety standards for design and production. 1 The pressure measured by the digtal manifold pressure tester is gauge pressure. 2 Pressure testing ranges from -101Kpa to 6Mpa (-0.1bar to 60bar). 3 The limit pressure is 10 Mpa (100 bar). 4 The maximum operating pressure of standard hose is 600 PSI (approximate 4.13 Mpa, 41.3 bar). The limit pressure is 3000 PSI approximate 20.68 Mpa, 206.8 bar. 5 Please confirm the rated pressure value of the tested equipment before testing. Do not use it if it exceeds the range of the instrument. Also for DY517A, if the packed. Hoses does not match the pressure requirement, you can use suitable replacements for testing. 6 Do not use and store the instrument in high temperature, high humidity, flammable, explosive and strong electromagnetic fields. 7 Please do not change the instrument internal circuit, to avoid any damage of the instrument or danger occurring. 8 Please wear qualified protective equipment to protect user during testing. 9 Please use the instrument in a well-ventilated environment to prevent inhalation of toxic gases. 1x Refrigerantion Digital Manifold Gauge.

1x User Manual (in English). Nowadays, you can meet AUTOOL on every continent and in 160 countries around the world. Vary from country to country, please understand.

The repair or replacement of products is determined by the actual breakdown situation of product. It is guaranteed that AUTOOL will use brand new component, accessory or device in terms of repair or replacement.

While the product is received for more than 90 days, the customer will bear the appropriate cost and we will provide the parts to the customer for replacement free of charge. The product breakdown because the user does not follow product instructions to use or maintain the product. AUTOOL was founded in 2014 in Shenzhen, China, inspired by a group of vehicle enthusiasts.

They have been in the field of car repair tools for more than ten years, dreaming of a simpler and more efficient solution for car repair! Product development, quality control, and customer service are always highest on our list of priorities.

Moreover, we will launch premium new products persistently, with patented technologies and innovative ideas embedded in. We are always responsible for our products, responsible for our customers and responsible for our partners.

We aspire to be an outstanding and competitive supplier of automotive tools, providing the customers with affordable and high-quality products. Wish we can solve the problem peacefully. We will reply you within 12 hours and do our best solve the problem with you Except on Weekends and Holidays.

The item "Digital Gauge Refrigeration Manifold for HVAC Vacuum Temp Pressure R134a A/C Set" is in sale since Thursday, September 16, 2021. This item is in the category "Business & Industrial\HVAC & Refrigeration\HVAC & Refrigeration Tools\HVAC & Refrigeration\ Gauges & Probes". The seller is "autool_official_store" and is located in Cranbury, New Jersey. This item can be shipped to United States.

  • Brand: AUTOOL
  • Gauge Purpose: Pressure
  • Type: Refrigeration Digital Gauge Meter
  • Refrigerant: R-123
  • Item Weight: 2kg
  • Gauge Fill: Dry
  • Item Length: 29cm
  • Item Width: 17cm
  • Features: Digital
  • Country/Region of Manufacture: China
  • Manufacturer Warranty: 3 Years
  • Vacuum Units: PSI
  • Pressure test range: 0 Kpa 6000 Kpa
  • Function 1: Evaporation pressure and temperature test
  • Function 2: Condensation pressure and temperature test
  • Function 3: High and low pressure temperature testing
  • Function 4: Pressure retaining leak test
  • Color: Black and Yellow
  • Items Included: Blue Low Side Hose
  • Model: LM120+
  • MPN: Does not apply
  • Year Manufactured: 2021
  • Function 5: Smart Digital Display Type Setting&Observable window


Digital Gauge Refrigeration Manifold for HVAC Vacuum Temp Pressure R134a A/C Set   Digital Gauge Refrigeration Manifold for HVAC Vacuum Temp Pressure R134a A/C Set