Manifold Gauge Set

Refrigeration Manifold Gauge Meter Digital HVAC Vacuum Pressure Temperature Test

Refrigeration Manifold Gauge Meter Digital HVAC Vacuum Pressure Temperature Test
Refrigeration Manifold Gauge Meter Digital HVAC Vacuum Pressure Temperature Test
Refrigeration Manifold Gauge Meter Digital HVAC Vacuum Pressure Temperature Test
Refrigeration Manifold Gauge Meter Digital HVAC Vacuum Pressure Temperature Test
Refrigeration Manifold Gauge Meter Digital HVAC Vacuum Pressure Temperature Test
Refrigeration Manifold Gauge Meter Digital HVAC Vacuum Pressure Temperature Test
Refrigeration Manifold Gauge Meter Digital HVAC Vacuum Pressure Temperature Test
Refrigeration Manifold Gauge Meter Digital HVAC Vacuum Pressure Temperature Test
Refrigeration Manifold Gauge Meter Digital HVAC Vacuum Pressure Temperature Test
Refrigeration Manifold Gauge Meter Digital HVAC Vacuum Pressure Temperature Test
Refrigeration Manifold Gauge Meter Digital HVAC Vacuum Pressure Temperature Test

Refrigeration Manifold Gauge Meter Digital HVAC Vacuum Pressure Temperature Test   Refrigeration Manifold Gauge Meter Digital HVAC Vacuum Pressure Temperature Test
Refrigeration Digital Manifold Gauge Meter HVAC Vacuum Pressure Temperature Test. Pressure test unit: Kpa; Mpa; bar; inHg; PSI. Pressure test range: 0 Kpa - 6000 Kpa. Pressure test resolution: 1 Kpa. Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt. Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;). Vacuum test unit: Kpa; Mpa; bar; inHg; PSI. Vacuum test range: -101 Kpa - 0 Kpa. Vacuum test resolution: 1 Kpa.

Temperature test unit: °C (Celsius), °F (Fahrenheit). Temperature test range: -40°C-150°C (-40°F-302°F). 0.1°C (-40°C-99.9°C), 1°C (100°C-150°C). 0.1°F (-40°F-99.9°F), 1°F (100°F-302°F).

Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt. Built-in 89 kinds of refrigerant NIST: According to American NIST standard. Power Supply: 4 X 1.5V SIZE.

AA / LR6 Battery not include. R11 R13 R113 R114 R115 R116 R12 R123 R124 R125 R1270 R134A R14 R141B R142B R143A R152A R170 R21 R218 R22 R227EA R23 R236EA R245CA R245FA R290 R32 R401A R401B R401C R402A R402B R403A R403B R404A R404B R405A R406A R407A R407B R407C R407D R407E R408A R409A R41 R410A R410B R411A R411B R412A R413A R414A R414B R415A R415B R416A R417A R418A R419A R420A R421A R421B R422A R422B R422C R422D R423A R424A R425A R426A R427A R428A R50 R500 R501 R502 R503 R504 R507A R508A R508B R509A R600 R600A R717 R744(Co2) R1234. Standard -- The intelligent electronic refrigerant group instrument is an auxiliary instrument for the installation, testing and maintenance of refrigeration equipment such as air conditioners, fridge and cold storage. HVAC System Gauge Set has double pressure test, dual temperature test, digital readout, multi-unit switching, multi-mode function and built-in refrigerant database.

CONVENIENT-- The instrument can measure double pressure at the same time, as well as dual temperature measurement, with automatic multi-unit pressure conversion, automatic conversion of temperature Celsius / Fahrenheit. WHAT YOU CAN GET MORE -- Built-in 89 kinds of refrigerant pressure-evaporation temperature database, also calculate the subcooling superheat, to facilitate direct reading of operating process data. Also it tests percentage of vacuum measurement, pressure leak measurement, leak time speed record. It is deserved to have this multi-functional, accurate and simply operated digital manifold let you do the job right. DESIGN -- Large-size liquid crystal display, LCD backlight support, data display clear and easy to read, convenient light operation.

Long-life valve switches, 1/4-inch standard interface design to ensure that the instrument's durability and versatility. HIGH-PRECISION -- The instrument uses high-strength engineering plastic and flexible non-slip silicone design. The whole machine is solid and comfortable to hold. Built-in 32-bit digital processing unit and high-precision data acquisition unit, high data and stability. 1 The pressure measured by the digtal manifold pressure tester is gauge pressure.

2 Pressure testing ranges from -101Kpa to 6Mpa (-0.1bar to 60bar). 3 The limit pressure is 10 Mpa (100 bar). 4 The maximum operating pressure of standard hose is 600 PSI (approximate 4.13 Mpa, 41.3 bar).

The limit pressure is 3000 PSI approximate 20.68 Mpa, 206.8 bar. Do not use and store the instrument in high temperature, high humidity, flammable, explosive and strong electromagnetic fields. Please do not change the instrument internal circuit, to avoid any damage of the instrument or danger occurring. Please wear qualified protective equipment to protect user during testing.

Please use the instrument in a well-ventilated environment to prevent inhalation of toxic gases. Please confirm the rated pressure value of the tested equipment before testing. Do not use it if it exceeds the range of the instrument.

Nowadays, you can meet AUTOOL on every continent and in 160 countries around the world. Vary from country to country, please understand.

The repair or replacement of products is determined by the actual breakdown situation of product. It is guaranteed that AUTOOL will use brand new component, accessory or device in terms of repair or replacement. While the product is received for more than 90 days, the customer will bear the appropriate cost and we will provide the parts to the customer for replacement free of charge. The product breakdown because the user does not follow product instructions to use or maintain the product. AUTOOL was founded in 2014 in Shenzhen, China, inspired by a group of vehicle enthusiasts.

They have been in the field of car repair tools for more than ten years, dreaming of a simpler and more efficient solution for car repair! Product development, quality control, and customer service are always highest on our list of priorities.

Moreover, we will launch premium new products persistently, with patented technologies and innovative ideas embedded in. We are always responsible for our products, responsible for our customers and responsible for our partners. We aspire to be an outstanding and competitive supplier of automotive tools, providing the customers with affordable and high-quality products. Wish we can solve the problem peacefully. We will reply you within 12 hours and do our best solve the problem with you Except on Weekends and Holidays.

The item "Refrigeration Manifold Gauge Meter Digital HVAC Vacuum Pressure Temperature Test" is in sale since Sunday, February 7, 2021. This item is in the category "Business & Industrial\HVAC & Refrigeration\HVAC & Refrigeration Tools\HVAC & Refrigeration\ Gauges & Probes". The seller is "autool_official_store" and is located in Walton, Kentucky. This item can be shipped to United States.

  • Brand: AUTOOL
  • Gauge Purpose: Pressure
  • Type: Manifold, Gauge & Hose Set
  • Vacuum Units: PSI
  • Items Included: Blue Low Side Hose
  • MPN: Does Not Apply
  • Features: Digital
  • Country/Region of Manufacture: China
  • Manufacturer Warranty: 3 Years
  • Maximum PSI: 300 PSI
  • Pressure test range: 0 Kpa 6000 Kpa
  • Pressure test resolution: 1 Kpa
  • Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt
  • Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;)
  • Vacuum test range: -101 Kpa 0 Kpa
  • Temperature test unit: °C (Celsius), °F (Fahrenheit)
  • Temperature test range: -40°C150°C (-40°F302°F)
  • Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt
  • Refrigerant: R11 R13 R113 R114 R115 R116
  • Model: lm120
  • Color: Black


Refrigeration Manifold Gauge Meter Digital HVAC Vacuum Pressure Temperature Test   Refrigeration Manifold Gauge Meter Digital HVAC Vacuum Pressure Temperature Test